| Specifications: | ||
|
Wetted Parts |
Diaphragm: Buna-N (optional EPDM or Viton®) |
|
|
Operating Temperature |
see table below |
|
|
Switch |
see table below |
|
|
Electrical Termination |
DIN 43650A, IP65 Terminals |
|
|
Proof Pressure |
7500 psi (517 bar) except Range 10: 500 psi (35 bar) |
|
| Burst Pressure | 9000 psi (600 bar) | |
|
Approvals |
CE, UL Approved units available, consult factory |
|
|
Weight, Approximate |
0.5 lbs. (0.23 kg) |
|
| Recommended Operating Temperature Limits* | |||
|
Diaphragm Material |
-A, -B, -C Circuit without -RD |
-AA, -BB, -CC Circuit or -RD |
|
|
Nitrile |
15°F to 185°F (-10°C to 85°C) |
15°F to 250°F (-10°C to 121°C) |
|
|
Viton® |
0°F to 185°F (-18°C to 85°C) |
0°F to 250°F (-18°C to 121°C) |
|
|
EPDM |
-10°F to 185°F (-23°C to 85°C) |
-10°F to 250°F (-23°C to 121°C) |
|
|
Neoprene |
-10°F to 185°F (-23°C to 85°C) |
-10°F to 250°F (-23°C to 121°C) |
|
* Switches may function below the cold temperature limit but the setpoints and deadband will increase. Consult factory for details.
| Switch Ratings | |||
|
Electrical Switch Ratings |
AC |
DC |
|
|
-A, -B, -C without -G |
5 amps @ 125/250 Volts |
5 amps resistive, 3 amps inductive @ 28 Volts |
|
|
-A, -B, -C with -G |
1 amp @ 125 Volts |
1 amp resistive, 0.5 amps inductive @ 28 Volts |
|
|
-AA, -BB, -CC without -G |
2 switches rated 5 amps @ 125/250 Volts |
2 switches rated 5 amps resistive, 3 amps inductive @ 28 Volts |
|
|
-AA, -BB, -CC with -G |
2 switches rated 1 amp @ 125/250 Volts |
2 switches rated 1 amp resistive, 0.5 amps inductive @ 28 Volts |
|
| Repeatability / Deadband | |||
|
Pressure Range Code |
Pressure Range |
Repeatability |
Average Deadband* |
|
-A, -B, and -C Circuits |
|||
|
10 |
5-25 psi (0.35-1.7 bar) |
± 1.0 psi (0.07 bar) + 2% of setting |
3 psi (0.21 bar) + 5% of setting |
|
20 |
15-75 psi (1-5.2 bar_ |
± 2.5 psi (0.17 bar) + 2% of setting |
5 psig (0.34 bar) + 10% of setting |
|
30 |
50-150 psi (3.5-10.3 bar) |
± 6 psi (0.41 bar) + 2% of setting |
15 psig (1.03 bar) + 13% of setting |
|
40 |
150 - 500 psi (10.3-34.5 bar) |
± 15 psi (10.3 bar) + 2% of setting |
25 psi (1.72 bar) + 14% of setting |
|
50 |
500 - 1750 psi (34.5-121 bar) |
± 25 psi (1.72 bar) + 2% of setting |
55 psi (3.79 bar) + 15% of setting |
|
60 |
1000 - 3500 psi (69-241 bar) |
± 45 psi (2.41 bar) + 3% of setting |
100 psig (6.89 bar) + 16% of setting |
|
70 |
2500-6000 psi (172-414 bar) |
± 80 psi (5.51 bar) + 4% of setting |
200 psi (13.8 bar) + 17% of setting |
|
-AA, -BB, and -CC Circuits** |
|||
|
10 |
5-25 psi (0.35-1.7 bar) |
± 1.5 psi (0.10 bar) + 3% of setting |
2 psi (0.14 bar) + 5% of setting |
|
20 |
15-75 psi (1-5.2 bar) |
± 3.5 psi (0.24 bar) + 3% of setting |
4 psig (0.28 bar) + 8% of setting |
|
30 |
50-150 psi (3.5-10.3 bar) |
± 9 psi (0.62 bar) + 3% of setting |
13 psig (0.90 bar) + 10% of setting |
|
40 |
150-650 psi (10.3-44.8 bar) |
± 22 psi (1.51 bar) + 3% of setting |
21 psi (1.72 bar) + 11% of setting |
|
50 |
500-1750 psi (34.5-121 bar) |
± 35 psi (2.41 bar) + 3% of setting |
45 psi (3.10 bar) + 12% of setting |
|
60 |
1000-3500 psi (69-241 bar) |
± 60 psi (4.14 bar) + 4% of setting |
80 psi (5.52 bar) + 13% of setting |
|
70 |
2500-6000 psi (172-414 bar) |
± 100 psi (6.89 bar) + 5% of setting |
160 psi (11.0 bar) + 14% of setting |
* In certain applications, deadband can be tailored and controlled to customer specifications. Consult factory for details.
** Operation of both switches in most cases will not be simultaneously but will occur within the specifications listed. Deadband figures already reflect the improvement from the -RD option which is automatically included in the -AA, -BB, and -CC circuits.
Stoc disponibil: Intreaba
Cos de cumparaturi (0 produse)