Mounting Types:
Each mounting type can be configured with stem lengths (Lo) and float materials indicated in the table below.
|
Type 1
|
Type 2
|
|
|
Flange is moveable, allowing stem and float to position to be adjusted when installed. May be bonded into set position if desired.
|
Designed for consistant use in same type of container. Buna N gasket provides snug seal.
|
|
|
|
|
| Mounting Hole Dia. |
1.20"/1.25"
(30.5 mm/31.75 mm)
|
1.31"/1.32"
(33.3 mm/33.5mm)
|
| Stem, Mounting and Collar Material |
Polysulfone
|
Polysulfone with Buna N Gasket
|
| Pressure Rating (mounting) |
Atmosphere (Not recommended for pressurized applications)
|
|
| Fluid Barb | Compatible 3/16" I.D. Hose (Options Available) | |
| Max. Length (Lo) | 15 inches (38 mm) ± 1/16" (2 mm) | |
| Mounting Position | Vertical ± 30° Inclination | |
| Mounting Campatibility | Cubitainer® Style Opening | Tank Wall Thickness 1/32" - 1/8" (0.79mm - 0.3.17 mm) |
| Stem and Mounting Material | Polysulfone, Noryl® |
| Max Length Lo | 20" (50 cm) tolerance of Lo = ±1/16" (2 mm)< /FONT > |
| Mounting Position | Vertical ± 30° Inclination |
Float Types:
A single float type is selected for use at all actuation points.
|
Electrical Specifications:
Typically, one float is required for each point at which you need a switch action to occur. The number of actuation levels available depends on the Group Type Wiring selected: see below.
Group I Wiring: 1 to 4 Actuation Levels
Group II Wiring: 1 to 2 Actuation Levels
Switch (SPST, N.O. or N.C.: 10/20/50/100 VA
Notes:
1. Other wiring options available. Consult factory.
2. Consult factory for load information.
| Actuation Level Dimensions | |||||||||||||||||||||||||||||
*Actuation level distances and Lo (overall unit length) are measured from inner surfaces of mounting plug or lfnage. See mounting types on for Lo reference point. Switch actuation levels are determined following the guidelines below. A= Minimum distance to highest actuation level. B= Minimum distance between actuation levels. C= Minimum distance between two actuation levels with one float (Note: One float for two levels can be used only when low level is N.C. dry and high level is N.O. dry). D= Minimum distance from end of unit to lowest level. |
|||||||||||||||||||||||||||||
Notes: 1. Actuation levels are calibrated on ascending fluid level with water, specific gravity 1.0 , as the calibrating fluid, unless otherwise specified. |
|||||||||||||||||||||||||||||
Stoc disponibil: Intreaba